Get a Quote

If you want our products, you contact me.

Email:[email protected]
  • Popular BHO extractor closed loop

    BHO extractor closed loop

    Sells 1 lb, 10 lb, 20 lb, 50 lb and other closed-loop extractors, which are made of stainless steel, are inexpensive and have high extraction efficiency.

  • Popular SPD2L short path distillation

    SPD2L short path distillation

    Sells a complete set of SPD-2L mini short-path distillation equipment, which is widely used in pharmaceutical, laboratory fractionation and purification, food and beverage, essential oil and other industries.

  • Popular RE5299 rotary evaporator

    RE5299 rotary evaporator

    Our company's rotary evaporator RE-5299 rotary evaporator uses high borosilicate glass, with sufficient storage, cheap and good quality.

  • Popular RE201D 301 501 rotary evaporator

    RE201D 301 501 rotary evaporator

    RE-201D RE-301 RE-501 rotary evaporator is a small rotary evaporator (mini rotary evaporator), beautiful appearance, small and light, top-rotating sealed, good vacuum.

  • Popular S80L 100L glass jacketed reactor

    S80L 100L glass jacketed reactor

    Is specializes in manufacturing and selling laboratory large-capacity glass reactors. Double-layer glass reactors can be customized and processed according to customer needs. The design is unique, safe and convenient.

  • Popular S10L 20L 30L 50L glass jacketed reactor

    S10L 20L 30L 50L glass jacketed reactor

    Is specializes in manufacturing and selling S-10L S-20L S-30L S-50L laboratory glass reactors, which can perform various solvent synthesis reactions under constant temperature conditions.

  • Popular FD03H freeze dryer

    FD03H freeze dryer

    Home lab freeze dryer is a mini vacuum freeze dryer. We are a freeze dryer manufacturer in China. We sell freeze dryers, which are very suitable for home use.

  • Popular DZF6500 vacuum drying oven

    DZF6500 vacuum drying oven

    The vacuum drying oven with vacuum pump can achieve the effect of vacuum drying.Provides vacuum drying ovens of various specifications.

rotary evaporator precautions

Principle of rotary evaporator - Lab Instrument …

The main components of a rotary evaporator. 1.A motor unit that rotates the evaporation flask or vial containing the user’s sample. 2.A vapor duct that is the axis for sample rotation, and is a vacuum-tight conduit for the vapor being …

Maintenance Precautions Of Lab Rotary Evaporator. Home; Products. Rotary Evaporator. 310rpm Oil & Water Bath, LCD Display Rotary Evaporator; 310rpm Oil & Water Bath, Color/Touch Screen Rotary …

How to use rotary evaporation for freeze drying sample …

The second option is to use a rotary evaporator. With this method, you obtain a nice evenly distributed area of frozen sample. The sample preparation here is slower than with option one, as you can only process one sample at a time. However, the downstream freeze-drying process is significantly sped-up when you freeze samples with a rotary

Rotary Evaporators | Fisher Scientific

Meet the essential needs of classical laboratory appliions with this rotary evaporator. Buchi™ Rotavapor™ R-100 Rotary Evaporators are capable of a manually adjustable rotation speeds of 20 to 280rpm and equipped with an action jack lift for manual lifting of the evaporating flask. Pricing and Availability.

Rotary Evaporator Fact Sheet - UMass Amherst

Rotary Evaporator Fact Sheet . What are Rotary Evaporators? A rotary evaporator (also called as “rotavap” or “rotovap”) is a device used in labs for the efficient and gentle removal of solvents from samples by evaporation. The picture on the right shows what a typical rotary evaporator includes. What are Potential Hazards?

Method and precautions during use of rotary evaporator - LABOAO

Sep 24, 2014· 1. The glass parts should be handled gently, washed and dried. 2. The heating tank should be energized after water injection, no dry burning. 3. The grinding equipment used should be evenly coated with a small amount of vacuum grease before installation. 4. The precious solution should be simulated first.

Rotary Evaporators | Fisher Scientific

Bump Trap, 250mL, Rotary Evaporator, Modified, 24/40 Top Outer, 14/20 Lower Inner. Similar to CG-1320, but with the addition of two 4mm drain holes at the base of the inner tube to allow solvent to drain back into the evaporation flask. Traps have a 24/40 top outer joint and the listed size of lower inner joint.

Rotary Evaporator - Safety

Users of rotary evaporation equipment must take precautions to avoid contact with rotating parts, particularly entanglement of loose clothing, hair, or necklaces. Under these circumstances, the winding action of the rotating parts can draw the users into the apparatus resulting in breakage of glassware, burns, and chemical exposure.

Precautions when using rotary evaporato +8615890068607; Home; About Us; Product. Rotary Evaporator; Glass Reactor; Steam Sterilizer; Freeze Dryer; Spray Dryer; Rotary Evaporator. 5L Rotary Evaporator; 50L Rotary Evaporator; 30L Rotary Evaporator; 20L Rotary Evaporator; 10L Rotary Evaporator; 5L …

Rotary Evaporators | Fisher Scientific

BUCHI Rotavapor™ R-300 Rotary Evaporator with Controller and V-300 Pump. The R-300 meets the highest expectations in convenience and versatility. Its modular design allows extension of the Rotavapor™ R-300 to a fully integrated system where a central interface regulates each component. Pricing and Availability.

50L Rotary Evaporator - 50 Liters Vacuum Evaporators/Rotovap …

Precautions When Unloading, Filling, and Closing The 50L Rotary Evaporator After turning on the 50L rotary evaporator find out the comparison positions for all components. When removing the device, hold the stand with one hand and the base with the other side or gradually remove it with both sides.

Best Practices for Rotary Evaporator Maintenance

Feb 21, 2020· Maintaining your rotary evaporator properly can help ensure it performs efficiently and increase the lifespan of your unit. Best practices for maintaining your rotovap include: Cleaning your unit properly Not leaving water in your bath Checking glassware for damage Not setting the speed too high Changing parts as needed

Rotary Evaporator - ExtractionSolution

A Rotary Evaporator is a device used in extraction laboratories for efficient and gentle distillation of solvents from samples by evaporation. Rotary evaporation is most often and conveniently applied to separate “low boiling” solvents such a butane or …

Safety And Precautions Of Rotary Evaporator

14. Ensure speed dial is to zero and turn off motor switch the rotary evaporator. 15. If finished for the day turn off water bath and power points, and leave the rotary evaporator and work area in a safe, clean and tidy state. Section 4 – Spill Procedure and Waste Disposal 1. Consult SDS of specific chemical for spill procedure. 2.

Rotary Evaporator - Safety

Users of rotary evaporation equipment must take precautions to avoid contact with rotating parts, particularly entanglement of loose clothing, hair, or necklaces. Under these circumstances, the winding action of the rotating parts can draw the users into the apparatus resulting in breakage of glassware, burns, and chemical exposure.

Rotary evaporator with recirculating chiller and vacuum pump price

Rotary evaporator is an indispensable instrument and equipment for evaporation, concentration, crystallization, drying, separation, solvent recovery and other processes. It is widely used in scientific research and production processes in medicine, chemical, biological products and other industries.Proper use of the rotary evaporator and proper

Standard Operating Procedure - Rotary Evaporator

the rotary evaporator control panel. 15. Use the dial on the rotary evaporator control panel to set the desired spin speed of the condenser. 16. If the desired evaporation should be timed, press the timer button on the rotary evaporator control panel and use the dial to set a time in minutes, or press the int

Small rotary evaporator use precautions - Exhibition - Gioglass

Dec 14, 2018· Small rotary evaporator use precautions. Small rotary evaporator use precautions. Call us on: +86-21-58085662 E-mail: [email protected] Home; About Us; Product. Small rotary evaporators are used for standard distillation, crystallization, product concentration, powder drying, and separation of one or more solvents.

How to use a Rotary Evaporator

Apr 01, 2010· 1. The solvent collection flask of the unit should always be emptied prior use to prevent accidentally mixing of incompatible chemicals. SAFETY FIRST! 2. The flask with the solution is placed on the rotary evaporator. The use of a bump trap prevents the solution from accidentally splashing into the condenser (and being contaminated).

Rotary Evaporator (Rotovap) Issues and the Smart Solution

Mar 11, 2019· Though Rotary Evaporators do have their use in common appliions, as a technology developed over 50 years ago, due to certain design limitations there are certain fundamental issues that cannot be avoided, even when taking the most careful precautions.

Rotary Evaporation: Laboratory Appliions - Scitek

Rotary Evaporation. Rotary evaporators are commonly used in chemistry related environments for the efficient and gentle removal of solvents from samples by evaporation under vacuum. The evaporator consists of a …

Precautions for the use of rotary evaporator

Precautions for the use of rotary evaporator Rotary evaporator is one of our main products,its Its supporting equipment is recirculating chiller and circulating water vacuum pump . Rotary evaporator is an indispensable instrument and equipment for evaporation, concentration, crystallization, drying, separation, solvent recovery and other processes.

Method and precautions during use of rotary evaporator

Method and precautions during use of rotary evaporator Technical Knowledge 2014-09-26 10:11:28. Rotary evaporators are primarily used to continuously distill large amounts of volatile solvents under reduced pressure. In particular, the concentration of the extract and the distillation of the receiving liquid in the chromatographic separation

Standard Operating Procedure - Rotary Evaporator

the rotary evaporator control panel. 15. Use the dial on the rotary evaporator control panel to set the desired spin speed of the condenser. 16. If the desired evaporation should be timed, press the timer button on the rotary evaporator control panel and use the dial to set a time in minutes, or press the int

Rotary Evaporator Fact Sheet - UMass Amherst

1. Wear lab coats, eye protection (safety glasses or goggles), closed-toes shoes, and appropriate gloves while operating the equipment. 2. Tie back long hair and do not wear loose items to avoid entanglement. 3. Ensure that the apparatus is maintained in a good working order. Seals should be checked periodically and replaced as necessary.

Precautions for purchasing a rotary evaporator

At present, there are many brands of rotary steaming instruments on the market. Many users do not know how to buy them in the face of so many brands. In response to such a situation, the rotary evaporator manufacturer ZZKD has compiled the precautions for the purchase of rotary evaporators, hoping to help everyone. Make an purchase:

Rotary evaporator and additional equipment | Breaking Bad

Feb 26, 2022· Rotary evaporator. A rotary evaporator (rotovap) is a device used in chemical laboratories for the efficient and gentle removal of solvents from samples by evaporation, as well as for the separation of liquids. When referenced in the chemistry research literature, description of the use of this

Rotary Evaporator (Rotovap) Issues and the Smart Solution

Mar 11, 2019· 1. bumping and annihilating substances, 2. slow evaporation, especially for DMSO / DMF and other high-boiling point substances and 3. difficulty working with small volumes, all of which can present larger problems for your research. Do you need a solution for all these issues? The Smart Evaporator is a solution!