Get a Quote

If you want our products, you contact me.

Email:[email protected]
  • Popular BHO extractor closed loop

    BHO extractor closed loop

    Sells 1 lb, 10 lb, 20 lb, 50 lb and other closed-loop extractors, which are made of stainless steel, are inexpensive and have high extraction efficiency.

  • Popular SPD2L short path distillation

    SPD2L short path distillation

    Sells a complete set of SPD-2L mini short-path distillation equipment, which is widely used in pharmaceutical, laboratory fractionation and purification, food and beverage, essential oil and other industries.

  • Popular RE5299 rotary evaporator

    RE5299 rotary evaporator

    Our company's rotary evaporator RE-5299 rotary evaporator uses high borosilicate glass, with sufficient storage, cheap and good quality.

  • Popular RE201D 301 501 rotary evaporator

    RE201D 301 501 rotary evaporator

    RE-201D RE-301 RE-501 rotary evaporator is a small rotary evaporator (mini rotary evaporator), beautiful appearance, small and light, top-rotating sealed, good vacuum.

  • Popular S80L 100L glass jacketed reactor

    S80L 100L glass jacketed reactor

    Is specializes in manufacturing and selling laboratory large-capacity glass reactors. Double-layer glass reactors can be customized and processed according to customer needs. The design is unique, safe and convenient.

  • Popular S10L 20L 30L 50L glass jacketed reactor

    S10L 20L 30L 50L glass jacketed reactor

    Is specializes in manufacturing and selling S-10L S-20L S-30L S-50L laboratory glass reactors, which can perform various solvent synthesis reactions under constant temperature conditions.

  • Popular FD03H freeze dryer

    FD03H freeze dryer

    Home lab freeze dryer is a mini vacuum freeze dryer. We are a freeze dryer manufacturer in China. We sell freeze dryers, which are very suitable for home use.

  • Popular DZF6500 vacuum drying oven

    DZF6500 vacuum drying oven

    The vacuum drying oven with vacuum pump can achieve the effect of vacuum drying.Provides vacuum drying ovens of various specifications.

vacuum pump user manual,

Vacurect User Manual - Health Connection

vacuum pressure by pressing down on the tension system. This action breaks the vacuum that releases the pressure and allows the user to remove the pump. The tension system is left in place at the base of the penis, capturing the blood in the penis and maintaining the erection. After use, the tension system is removed allowing the blood to

Diaphragm Vacuum Pumps - User Manual Search Engine

vacuum. The DIVAC T pumps have been spe-cially developed as backing pumps for wide range high vacuum turbomolecu-lar pumps. They meet the require-ments for a dry vacuum and a long service life. DIVAC T pumps may be used both free-standing and integrated in applica-tions or certain devices, and for this reason they are used in the areas of

OPERATING INSTRUCTIONS - Lesker

Jan 07, 2015· INLET Pump inlet connection PUMP EXHAUST Pump exhaust connection This label warns the user against possible risk of injury due to any hand contact with hot surfaces. It states that protective gloves should be used before performing any intervention. This label informs the user, that moving pa rts present inside the pump could cause per-

RA 0400 C, RA 0502 C, RA 0630 C - Busch Vacuum Solutions

Oil-Lubried Rotary Vane Vacuum Pumps RA 0400 C, RA 0502 C, RA 0630 C RC 0400 C, RC 0502 C, RC 0630 C US Version 0870207738/-_en / Original instructions / Modifiions reserved4/5/2018 Busch Manufacturing LLC 516 Viking Drive ia Beach, VA 23452 USA. Table of Contents

Section 1 - ehs.washington.edu

Standard Operating Procedures for Routine Maintenance of Diaphragm Vacuum Pumps. This is an SOP template and is not complete until: 1) lab and equipment specific information is entered into the box below 2) lab and equipment specific protocol/procedure is added to the protocol/procedure section 3) Lab and equipment

Ideal Vacuum | Vacuum Pump User Manuals PDF Downloads

What you need

MS40+ Single Stage Rotary Vane Pumps - Agilent

Vacuum Products Division . Via F.lli Varian, 54 It calls attention to an operating . 10040 Leinì (TO) ITALY . Warranty . MS40+ Single Stage Rotary Vane Pumps User Manual / 87-901-008-01 (E) 11/90 Immagazzinamento Durante il trasporto e l''immagazzinamento delle pompe non devono

Vacuum Pumps VP Series User Manual - LabTech

VP SERIES – User Manual 10 4. TROUBLESHOOTING The Pump Does Not Start After Switching The Power On Check the power cord and ensure it is plugged in. Check whether or not the system has higher negative pressure. This can be judged from the vacuum gauge. If negative the pressure is bigger than -0.05MPa the pump cannot start. The

-san- Pascal series - Vacuum Pump Supply

Oil seal rotary vane pumps are used in all vacuum technology appliions. They can be used on their own to achieve a maximum vacuum of 0.75 Torr (10-3 ar), or in pumping asselies, e.g. at the exhaust of a diffusion pump or turbomolecular pump. Standard pumps for several purposes (non-corrosive appliions).

0870155464 RA0063-0100F A0002 IM en - Busch Vacuum …

In this instruction manual, we consider that the term ‘machine’ refers to the ‘vacuum pump’. Product Description | 2 0870155464_RA0063-0100F_A0002_IM_en 5 / 24 Operating Principle2.1 The machine works on the rotary vane principle. The oil seals the gaps, lubries the vanes and takes away compression heat.

Section 1 - ehs.washington.edu

Standard Operating Procedures for Routine Maintenance of Diaphragm Vacuum Pumps. This is an SOP template and is not complete until: 1) lab and equipment specific information is entered into the box below 2) lab and equipment specific protocol/procedure is added to the protocol/procedure section 3) Lab and equipment

Leybold Manuals

Please enter the material nuer or serial nuer of your product in the search bar. You can find the material nuer (also called part nuer/ alog nuer) in several places: . Offer letter; Delivery note; Nameplate of the product

OPERATING INSTRUCTIONS - Lesker

Jan 07, 2015· INLET Pump inlet connection PUMP EXHAUST Pump exhaust connection This label warns the user against possible risk of injury due to any hand contact with hot surfaces. It states that protective gloves should be used before performing any intervention. This label informs the user, that moving pa rts present inside the pump could cause per-

Elitech Intelligent Vacuum Pump User Manual – ElitechEU

Sep 14, 2021· 1. Place on a flat surface. 2. Confirm the voltage and frequency at the outlet match with the vacuum pump specifiions. 3. Confirm the oil level is within the Min and Max level. 4. Remove the air inlet cap (1/4 SAE), connect the pumped system (make sure the pipe fitting is fit with the air inlet fitting). Tighten the air inlet andmake sure

Cook® Vacuum Pump | Cook Medical

Used to provide a low flow, regulated vacuum up to -500 mm Hg for general suction. A pedal activates the vacuum response at the needle tip. The pump maintains a constant vacuum at its set level. The boost button on the front panel increases the vacuum pressure to clear blockages in the ovum aspiration needle. A volume-adjustable tone indies when vacuum is applied.

PLATINUM

2 JB INDUSTRIES • PLATINUM OPERATING MANUAL • 800 323 0811 • SALESJBIND COM • JBIND COM INTRODUCTION Each PLATINUM ® vacuum pump has been factory tested to guarantee 15 microns (25,4000 Microns = 1 Inch of Hg) or better, and listed CFM performance The serial nuer has been recorded Complete and mail the enclosed Warranty Registration

Installation and Operating Manual - Maximum Vacuum

Start the pump with the inlet closed. Run the pump for a few minutes and then shut down. Check the oil level again and make sure the oil level is between the ¾ mark and full on the upper oil sight glass. Add oil, if necessary. Pump oil should only be added when the pump is off and circulating oil has sufficient time to return to the oil sump.

Section 1 - ehs.washington.edu

Standard Operating Procedures for Routine Maintenance of Diaphragm Vacuum Pumps. This is an SOP template and is not complete until: 1) lab and equipment specific information is entered into the box below 2) lab and equipment specific protocol/procedure is added to the protocol/procedure section 3) Lab and equipment

Vacuum Pump with RunQuick™ Oil Change System

• VP55/VP85 Vacuum Pump • (2) 8 Ounce Vacuum Pump Oil • Operator’s Manual • 1 Year Warranty! WARNINGS Ensure proper equipment grounding, electrical shock risk. Do not use to pump liquid refrigerant, explosion risk. Do not use to pump flammable media, explosion risk. Inhalation of high concentrations of refrigerant vapor can block

MANUAL

Spare part kit MINI pumps 5 - 28, NBR 3201097 Spare part kit MINI pumps 5 - 28, EPDM 3201097E Spare part kit MINI pumps 5 - 28, Viton® 3201097V Model MINI with connection plate Connections Compressed air Vacuum Design A in ABS M5 1/8” NPSF L7, M5L, M10L, X5L, X10L B in ABS 1/8” NPSF 3/8” NPSF L14, L28, M5L, M10L, M20L

Vacuum Pumps | Vacuum Research

Two Piston Pump Rebuild & Parts List. Oil Free Dry Vacuum Pumps Absolute 501 and Absolute 1201. Four Piston Pump Rebuild & Parts List. Two Stage Rotary Vane Vacuum Pump Manual Model 140-5. Two Stage Rotary Vane Vacuum Pumps Parts List Model 800-28, Model 600-21, Model 400-14, Model 200-7, Model 100-3.5. Two Stage Rotary Vane Vacuum Pumps Manual

DRY SCREW VACUUM PUMP USER MANUAL

DRY SCREW VACUUM PUMP USER MANUAL INSTALLATION OPERATION MAINTENANCE Models: ESPH 150 | ESPH 300 | ESPH 400 ESPH 800 DO NOT OPERATE WITHOUT READING MANUAL WARNING Doc. No. OMM-Dry Screw Vacuum Pumps Screw Vacuum Pumps (ESPH150, ESPH300, ESPH400, and ESPH800).You must operate the

Vacuum Pumps | Fisher Scientific

16. BUCHI Vacuum Pump V-600 for Rotavapor™ R-220 Pro Industrial Evaporator for multiple benchtop Rotavapors™. Vacuum Pump V-600 is a chemically resistant 3-stage diaphragm pump with silent and economical operation that makes it suited to work with the R-220 Pro or multiple benchtop Rotavapors™. Pricing & Availability.

Instruction Manual - Edwards

EN1012-2:1996+A1:2009 Compressors and Vacuum Pumps. Safety Requirements. Vacuum Pumps . EN60034-1:2010 Rotating electrical machines. Rating and performance . EN50581:2012 Technical Documentation for the Assessment of Electrical and . Electronic Products with respect to the Restriction of Hazardous . Substances . and fulfils all the relevant

Literature & Manuals | Robinair

SDS high vacuum pump oil Document # 552184) 34788NI, 34788NI-H, 34788NI-230 Operating Instructions - English (Document # 573104) Operating Instructions - Spanish (Document # …

Dry screw vacuum pump user manual

Dry screw vacuum pump of overview. This dry vacuum pump uses the pressure generated by two screw rotors to discharge the suction gas. The outline of the two screw rotors is a multi-stage curve, which can maintain a certain gap between the rotor and the rotor, and between the rotor and the shell so as to run smoothly.

User Manuals available online - Les équipements d''érablière CDL

User manual – 81125 and 81250 Reverse Osmosis Operation procedures – 81125 and 81250 Reverse Osmosis. VACUUM PUMPS. CDL Vacuum pump. L-Series vacuum pump. L-Series vacuum pump MAINTENANCE. L-Series vacuum pump INSTALLATION DIAGRAM. ELECTROFUSION. Training guide for electrofusion.

Oerlikon Leybold Vacum Pump D40B, D65B, Operating

The Leybold TRIVAC B vacuum pump is designed for safe and efficient operation when used properly and in accordance with this manual. It is the responsibility of the user to carefully read and strictly observe all safety precautions described in this section and throughout the manual. This product must be operated and maintained by