Get a Quote

If you want our products, you contact me.

Email:[email protected]
  • Popular BHO extractor closed loop

    BHO extractor closed loop

    Sells 1 lb, 10 lb, 20 lb, 50 lb and other closed-loop extractors, which are made of stainless steel, are inexpensive and have high extraction efficiency.

  • Popular SPD2L short path distillation

    SPD2L short path distillation

    Sells a complete set of SPD-2L mini short-path distillation equipment, which is widely used in pharmaceutical, laboratory fractionation and purification, food and beverage, essential oil and other industries.

  • Popular RE5299 rotary evaporator

    RE5299 rotary evaporator

    Our company's rotary evaporator RE-5299 rotary evaporator uses high borosilicate glass, with sufficient storage, cheap and good quality.

  • Popular RE201D 301 501 rotary evaporator

    RE201D 301 501 rotary evaporator

    RE-201D RE-301 RE-501 rotary evaporator is a small rotary evaporator (mini rotary evaporator), beautiful appearance, small and light, top-rotating sealed, good vacuum.

  • Popular S80L 100L glass jacketed reactor

    S80L 100L glass jacketed reactor

    Is specializes in manufacturing and selling laboratory large-capacity glass reactors. Double-layer glass reactors can be customized and processed according to customer needs. The design is unique, safe and convenient.

  • Popular S10L 20L 30L 50L glass jacketed reactor

    S10L 20L 30L 50L glass jacketed reactor

    Is specializes in manufacturing and selling S-10L S-20L S-30L S-50L laboratory glass reactors, which can perform various solvent synthesis reactions under constant temperature conditions.

  • Popular FD03H freeze dryer

    FD03H freeze dryer

    Home lab freeze dryer is a mini vacuum freeze dryer. We are a freeze dryer manufacturer in China. We sell freeze dryers, which are very suitable for home use.

  • Popular DZF6500 vacuum drying oven

    DZF6500 vacuum drying oven

    The vacuum drying oven with vacuum pump can achieve the effect of vacuum drying.Provides vacuum drying ovens of various specifications.

7. explain how to safely remove specimens from a centrifuge

Fundamentals of Centrifuge Safety | CDC

Description. Centrifuges are instruments used to separate mixtures, based on particle size and density, by spinning the mixtures at high speeds. These instruments are essential tools in all types of laboratories. Serious injuries or potential exposures can occur if centrifuges are improperly used or maintained.

Laboratory handling of human biological specimen : Safety, …

Jul 14, 2017· Centrifuges used for spinning body fluids should have a sealed rotor and/or sealed buckets with transparent lids which allow staff to see if a breakage has occurred. In the event of a breakage during centrifugation, the whole bucket can be autoclaved before the lid is removed. Back to top. Human biological specimens in laboratory practical classes

Specimen Centrifuge - Equipment - PathLabTalk

Jan 29, 2013· Posted January 7, 2013. Actually, I am not looking for times/RPM for actual testing. I am looking for the specimen preparation piece. Our current centrifuge is set to spin our specimens for gel testing at 3500RPM for 5 minutes. Our lab is looking a standardizing to one centrifuge for the entire lab including coags which need platelet poor plasma.

Safety Considerations When Operating a Lab Centrifuge

Dec 19, 2018· In order to ensure you and your colleagues remain safe, there are several precautions to take, including: Use the centrifuge on a level surface. Check the unit before use. Inspect tubes before use. Check the maximum load tolerance and speed. Balance tubes correctly. Keep the lid closed during cycles.

Specimen Centrifuge - Equipment - PathLabTalk

Jan 29, 2013· Posted January 7, 2013. Actually, I am not looking for times/RPM for actual testing. I am looking for the specimen preparation piece. Our current centrifuge is set to spin our specimens for gel testing at 3500RPM for 5 minutes. Our lab is looking a standardizing to one centrifuge for the entire lab including coags which need platelet poor plasma.

03.0 Chemical Safety Practices and Procedures - Fred Hutch

Allow the centrifuge to come to a complete stop before opening. Wear a new pair of outer gloves to remove rotor and samples. Check inside of centrifuge for possible spills and leaks, and clean centrifuge and rotor thoroughly, if necessary. Wash hands after removing gloves. 3.3.2 Centrifuging Infectious Materials or Human Samples

Cleaning and Disinfecting Centrifuges - Ascend Reference Manual

1. Cleaning. Clean the centrifuge weekly using a mild detergent. Spills should be wiped up immediately. Clean both the exterior and the interior. Interior cleaning includes the interior bucket, specimen holder, rotor and rubber cushion. 2. Disinfecting. Disinfect using a 10% bleach solution (one part bleach to nine parts water).

Types of Centrifuge and Centrifugation (definition, principle, uses)

Jul 10, 2021· Centrifuge Rotors. Rotors in centrifuges are the motor devices that house the tubes with the samples. Centrifuge rotors are designed to generate rotation speed that can bring about the separation of components in a sample. There are three main types of rotors used in a centrifuge, which are: 1. Fixed angle rotors.

High-Speed Centrifuges for Lipemia Removal in Serum/Plasma …

Hettich high-speed centrifuges, the low-cost alternative for lipemia removal in serum/plasma samples: Save thousands in equipment costs as compared to ultracentrifuges (upwards of ~$15k) Successfully clear lipemic samples with no reagents or additives. Obtain versatility for multiple appliions with multiple rotor options and a compact footprint.

SPECIMEN COLLECTION, HANDLING, and TRANSPORT

4. STAT: If your specimen has a “STAT” priority, please call your ourier for pickup. Place the sample in a “Red” biohazard labeled specimen bag. The red bag will easily be seen as a STAT specimen upon delivery to the laboratory. 5. Other Requirements: Remove all needles and sharps from all specimens before transporting.

Chapter 3

A phlebotomist is working in the specimen processing area of the lab. Suddenly a co-worker who is removing specimens from a centrifuge collapses. The phlebotomist notices water leaking from a sink next to the centrifuge. Describe the steps necessary to …

Standard Operating Procedure Centrifuge Safety

before users are allowed to operate the centrifuges. • Operating and maintaining all centrifuges in accordance with manufacturer’s instructions and good safe laboratory procedures. • Reading and following all instructions for safe usage and maintenance of the centrifuge .

Chap 3 Critical Thinking Questions DONE.docx - Critical

A phlebotomist is working in the specimen processing area of the lab. Suddenly a coworker who is removing specimens from a centrifuge collapse. The phlebotomist notices water leaking from a sink next to the centrifuge. Describe the steps necessary to …

03.0 Chemical Safety Practices and Procedures - Fred Hutch

Allow the centrifuge to come to a complete stop before opening. Wear a new pair of outer gloves to remove rotor and samples. Check inside of centrifuge for possible spills and leaks, and clean centrifuge and rotor thoroughly, if necessary. Wash hands after removing gloves. 3.3.2 Centrifuging Infectious Materials or Human Samples

How to Handle & Dispose of Preserved Biological Specimens

specimens should be rinsed under a sink tap with several gallons of running water. Flush the dissection tray with tap water to remove any collected specimen dripping. Use paper towels or disposable absorbent material to gently dry the specimen and tray before beginning the dissection. 1. Wear safety glasses and do not wear contact lenses.

Laboratory-General Specimen Collection and Handling …

position. Do not centrifuge specimens at higher speed or for longer than necessary. Serum tubes should be centrifuged and separated promptly if they will not be delivered to the laboratory within four (4) hours of collection. Many analytes (e.g. - glucose, potassium, LDH, most enzymes, etc.) are affected by hemolysis

How to Use a Centrifuge: 14 Steps (with Pictures) - wikiHow

Nov 03, 2020· Wipe the outside of the tube with disinfectant before placing it in the centrifuge. Wiping the tube is particularly important if you are working with a biohazardous material. You want to limit any possible spills or aerosol formation of your sample. The best prevention is to wipe down the sample with a proper disinfectant before the spin begins. 4

Specimen Preparation | User Guide | LabCare PLUS

When specimen requirements call for a chilled specimen (2-8° C), the specimen is to be immediately placed in a small plastic tube bag, tied and placed in crushed ice or a mixture of ice and water. The recommended centrifuge time is15 minutes at 3,000 rpm. All specimens collected in tubes with gel barriers should be properly centrifuged

In order to safely run a sample in a centrifuge, it is important to

Mar 02, 2020· When the safety run sample should be in a centrifuge so the sample should be free from impurities.. Laboratory device: It is used to distinguish gases or liquids that depend upon the density is called a centrifuge.At the time When a vessel comprised of the sample should be spinning at a high speed so the separation took place since the centrifugal force pushes the …

Spills in a centrifuge - Princeton University

Spills in a centrifuge. 1. Put on lab coat, gloves and a face shield prior to opening centrifuge. Open carefully to assess the damage. 2. If the spill is contained within a closed cup, bucket or rotor, spray the exterior with disinfectant and allow at least 10 minutes of contact time. Remove the carrier to the nearest biosafety cabinet (BSC).

Sorian-Michelle-A.-Lab-safety.docx - 5. Demonstrate …

Sep 27, 2021· demonstrate on how safely remove specimens from a centrifuge. 1.allow the centrifuge to come to a complete stop before opening. 2.wear a new pair of outer gloves to remove rotor and samples. 3.check inside of centrifuge for possible spills and leaks, and clean centrifuge and rotor thoroughly, if necessary. 4.wash hands after removing …

Guidelines for Safe Work Practices in Human and Animal …

Jan 06, 2012· 3.1.5. Manual removal of sealed caps; specimen aliquotting and pipetting. Always remove caps behind a bench-fixed splash shield, or wear additional PPE appropriate to protect from splashes and aerosols. Place a gauze pad over the cap, and then slowly pry or push the cap off with an away-from-body motion.

How a Centrifuge Works - Drucker Diagnostics

To use a centrifuge machine: Insert the test tube sample into one of the portals. If needed based on the nuer of samples you are testing, insert test tubes filled with water for balance. Secure the lid and select desired settings. Start the centrifuge and wait for it to complete the cycle.

Module 7: Specimen Handling Flashcards - Quizlet

3. remove stopper if nec. properly 4. check that the labels on the specimen and aliquot tube match 5. work left to right using fresh pasteur pipet to aliquot correct amount 6. replace tubes into their appr. position in the rack 7. stopper aliquot tubes 8. double check specimens and accession # match 9. distribute specimens

The Importance of Proper Specimen Collection and Handling

Nov 24, 2015· Ten points of importance are: The laboratory should set technical policy; this is not the purview of the medical staff. Good communiion and mutual respect will lead to collaborative policies. The laboratory must follow its procedure manual. A specimen should be collected prior to administration of antibiotics.

Handling and Processing of Blood Specimens from Patients with …

Handling and Processing of Blood Specimens from Patients with COVID-19 for Safe Studies on Cell Phenotype and Cytokine Storm Cytometry A. 2020 Jul;97(7) :668-673. Few years ago, International Society for Advancement of Cytometry published guidelines to safely analyze and sort human samples that were revised in these days. We describe the

Exercise 1-Laboratory Safety Flashcards - Quizlet

Explain how to clean up broken glass. Sweep up immediately then place in sharps box. List the loion of the following safety items in the laboratory. First aid kit: Behind the computer. Nearest telephone: by front door. Eye wash station: Front doors and windows. Fire exits: Front and back of room. Fire extinguisher: In the back.

Cleaning and Disinfecting Centrifuges - Ascend Reference Manual

1. Cleaning. Clean the centrifuge weekly using a mild detergent. Spills should be wiped up immediately. Clean both the exterior and the interior. Interior cleaning includes the interior bucket, specimen holder, rotor and rubber cushion. 2. Disinfecting. Disinfect using a 10% bleach solution (one part bleach to nine parts water).