Get a Quote

If you want our products, you contact me.

Email:[email protected]
  • Popular BHO extractor closed loop

    BHO extractor closed loop

    Sells 1 lb, 10 lb, 20 lb, 50 lb and other closed-loop extractors, which are made of stainless steel, are inexpensive and have high extraction efficiency.

  • Popular SPD2L short path distillation

    SPD2L short path distillation

    Sells a complete set of SPD-2L mini short-path distillation equipment, which is widely used in pharmaceutical, laboratory fractionation and purification, food and beverage, essential oil and other industries.

  • Popular RE5299 rotary evaporator

    RE5299 rotary evaporator

    Our company's rotary evaporator RE-5299 rotary evaporator uses high borosilicate glass, with sufficient storage, cheap and good quality.

  • Popular RE201D 301 501 rotary evaporator

    RE201D 301 501 rotary evaporator

    RE-201D RE-301 RE-501 rotary evaporator is a small rotary evaporator (mini rotary evaporator), beautiful appearance, small and light, top-rotating sealed, good vacuum.

  • Popular S80L 100L glass jacketed reactor

    S80L 100L glass jacketed reactor

    Is specializes in manufacturing and selling laboratory large-capacity glass reactors. Double-layer glass reactors can be customized and processed according to customer needs. The design is unique, safe and convenient.

  • Popular S10L 20L 30L 50L glass jacketed reactor

    S10L 20L 30L 50L glass jacketed reactor

    Is specializes in manufacturing and selling S-10L S-20L S-30L S-50L laboratory glass reactors, which can perform various solvent synthesis reactions under constant temperature conditions.

  • Popular FD03H freeze dryer

    FD03H freeze dryer

    Home lab freeze dryer is a mini vacuum freeze dryer. We are a freeze dryer manufacturer in China. We sell freeze dryers, which are very suitable for home use.

  • Popular DZF6500 vacuum drying oven

    DZF6500 vacuum drying oven

    The vacuum drying oven with vacuum pump can achieve the effect of vacuum drying.Provides vacuum drying ovens of various specifications.

no solid after rotovap

Getting solids out of a round bottom after rotovap - reddit

Once you''ve rotovapped off your solvent you can add a different solvent that your product will not dissolve in or react with. Then scrape around the flask to get as much solid into a suspension as possible and filter it off with a Buchner funnel. Works a bit better than scraping the edges and trying to get the fine powder out with a spatula. 1

Rotovap questions - International Cannagraphic Magazine Forums

New Topics; Today''s Posts; Meer List; Calendar; Forum; Marijuana Growing; Cannabis Concentrates; If this is your first visit, be sure to check out the FAQ by clicking the link above. You may have to register before you can post: click the register link above to proceed. To start viewing messages, select the forum that you want to visit from the selection below.

AI Rotovaps for Solvent Recovery Fractional Distillation

Nov 04, 2015· Benefits of the Rotovap vs. Cold trap? A.Rotovap offers much closer control of evaporation of liquid phase materials due to smaller volume thus finer vacuum control. B.HOWEVER, vacuum oven’s deeper vacuum capabilities allow material to be degassed & recollected at lower temperatures. Do I need a vacuum pump? Yes, but not just any vacuum …

How Ecodyst’s Modern Rotovap Revolutionizes Rotovap Technology …

Mar 04, 2021· Please use one of the following formats to cite this article in your essay, paper or report: APA. Ecodyst. (2021, April 01). How Ecodyst’s Modern Rotovap Revolutionizes Rotovap Technology.

How to Clean a Rotovap - BenchFly

The protocol shows how insanely easy it can be to actually clean out the rotovap. No more taking the entire thing apart to wash out a little condensation or the residue left over after a major bump. It’s creative. Videos don’t have to be long. Heck, they don’t even have to include words (and sometimes they’re better without them)!

Rotary Evaporator (Rotovap) Issues and the Smart Solution

Mar 11, 2019· Bumping vs. No Bumping. Bumping is a common problem while using rotary evaporators, as samples being heated under vacuum in closed conditions causes the solvent to suddenly boil and “bump,” in other words erupt, usually quickly without warning. As the rotovap evaporates the solvent under vacuum, the solvent can be sucked up in its entirety

How Does the Rotary Evaporator Work? - Extraction Magazine

Dec 18, 2018· A rotary evaporator, or “rotovap” in lab jargon, is an instrument used in a chemistry lab to remove a volatile solvent from a liquid mixture. In a cannabis setting, the most common use for it is to remove ethanol from a winterized extract. The rotary evaporator functions on the general assumption that the boiling point of the solvent is

Any Rotovap Tips? : chemistry - reddit

the reason you spin on a rotovap is to increase the surface area exposed when evaporating, and disrupt the surface such that it doesn''t bump. I rotovap at a speed fast enough to ensure the liquid in the flask is swirling, and that an even thin layer is exposed to the vacuum on each rotation. this varies based on flask size, and liquid viscosity. and in later stages how much …

Rotovap for sale | eBay

USA Lab Equipment 110V 2L Rotary Evaporator Rotovap RE-200A - 1 Year Warranty. $1,598.00. $166.99 shipping. 65 watching. Buchi R-210 Rotovap Rotary Evaporator (1) 1 product ratings - Buchi R-210 Rotovap Rotary Evaporator . $396.00. Was: $495.00. $116.98 shipping. or Best Offer. Buchi R114 Rotovap complete.

Best Practices for Rotary Evaporator Maintenance

Feb 21, 2020· 2. Avoid Leaving Water in Your Bath It may seem convenient to simply leave the same water in your rotovap water bath for days or even weeks. After all, it’s not coming in contact with your sample, so it seems harmless enough. However, leaving water in the bath can lead to fouling due to dust, debris, and inevitable algae growth.

design has no solid bodies - Autodesk

Mar 30, 2015· design has no solid bodies uploaded iges file what else do I need to do to create a drawing. I am very new to this software. Thanks . message says design has no soid bodies. Report. 0 Likes Reply. Back to Topic Listing; Previous; Next; 4 REPLIES 4. Message 2 of 5 innovatenate. in reply to: pmproducts ‎03-30-2015 03:35 PM. Mark as New;

Rotovap Distillation: What Is A Rotary Evaporator? - BVV

Jul 21, 2017· Connect vacuum pump to cold trap and cold trap to rotovap vacuum port. Turn on heat bath and set to 40°C (113°F). Once heat bath and coil have reached the desired temperature, turn on rotovap motor and set speed to approximately 100 RPM. Start vacuum pump and allow it to pull down for a few minutes before beginning injection.

Question Using hexane as solvent for solvent extraction, still or rotovap?

Oct 04, 2017· Sep 27, 2017. 34 y/o from Azores, Portugal. Docta said: ↑. Start with Hexane it is a far superior solvent for extracting of things such as cannabis oils, when I say Hexane I mean n- hexane the aliphatic hydrocarbon. The alcohol is then used as a scrubber after the hexane has been evaporated to remove any residue.

How to Speed Up Your Rotary Evaporation Process

Jun 26, 2019· 3. Increasing the Bath Temperature. The water bath is responsible for one of the ways in which a rotovap speeds up evaporation. The water bath heats the solvent, increasing the rate of evaporation. However, it’s important not to be …

How can I used rotary evaporator to obtain my solid from

Jun 07, 2016· At 130 ar the boiling point of ethylene glycol is around 140-150 oC. To be able to remove at 55 oC you need min 2.6 ar, but at this pressure you will not able to remove anything from ethylene

How Does the Rotary Evaporator Work? - Extraction Magazine

Dec 18, 2018· A rotary evaporator, or “rotovap” in lab jargon, is an instrument used in a chemistry lab to remove a volatile solvent from a liquid mixture. In a cannabis setting, the most common use for it is to remove ethanol from a winterized extract. The rotary evaporator functions on the general assumption that the boiling point of the solvent is

Rotary Evaporation in the Kitchen - Cooking Issues

May 19, 2009· Fill water bath (usually 2/3 full) with warm to hot water, set the temperature and turn it on. Put the thermometer from the rotovap unit into the water bath. Clean the vapor duct area and install the vacuum seal. Install a DRY evaporation flask. Close off (seal) the receiving flask/pump takeoff area.

Why a Rotary Evaporator Won''t Hold Vacuum and What to Do …

Jan 12, 2018· The transformation of a liquid into a gas involves a very large increase in volume. At standard temperature and pressure 1 mole gas = 22.4 L. Meaning, for example, that 18 mL of H 2 O (1 mole) converts into 22.4 l of gas. The same is true for 104 mL of diethyl ether, 64 mL dichloromethane, and 132 mL of hexane.

AI Rotovaps for Solvent Recovery Fractional Distillation

Nov 04, 2015· Benefits of the Rotovap vs. Cold trap? A.Rotovap offers much closer control of evaporation of liquid phase materials due to smaller volume thus finer vacuum control. B.HOWEVER, vacuum oven’s deeper vacuum capabilities allow material to be degassed & recollected at lower temperatures. Do I need a vacuum pump? Yes, but not just any vacuum …

Rotary Evaporator | Ethanol extraction CBD technology equipment - Rotovap

Install the receiving flask and evaporating flask on the rotary evaporator. After applying vacuum grease evenly on the grinding mouth, clamp it with a clamp. 6. Add appropriate amount of water to the water bath, turn on the power, set the heating temperature, and the heating indior light is on, and it can be used normally. 7.

Rotavapor® R-100 | Buchi

Solid and proven. The robust design of Rotavapor® R-100 ensures reliable, quick, and ergonomic operation with a smooth manual lift mechanism. Possibility to have an IQ/OQ: No; Related Parts & Accessories Learn more about Parts & Accessories. Evaporating flask, glass, SJ29/32, 1000 mL. Evaporating flask, glass, SJ29/32, 1000 mL. Vacuum seal

Rotary Evaporation in the Kitchen – Cooking Issues

May 19, 2009· Fill water bath (usually 2/3 full) with warm to hot water, set the temperature and turn it on. Put the thermometer from the rotovap unit into the water bath. Clean the vapor duct area and install the vacuum seal. Install a DRY evaporation flask. Close off (seal) the receiving flask/pump takeoff area.

Rotary evaporator - Wikipedia

A rotary evaporator (rotovap) is a device used in chemical laboratories for the efficient and gentle removal of solvents from samples by evaporation.When referenced in the chemistry research literature, description of the use of this technique and equipment may include the phrase "rotary evaporator", though use is often rather signaled by other language (e.g., "the sample …

Re: No Solid Color - Adobe Support Community - 11536178

Nov 04, 2020· Hello Barb, Paola here! First of all, thanks to try to understand and solve these problems for us 🙂. I just opened my Photoshop and the same issue with solid color. the operational System here is Windows 10 and Photoshop updated today. I reseted the preferences as you sugest, and the solid color continues to blink and not happening.

IKA Rotary Evaporators Rotary evaporator distilling distillation …

No. 0010007358. IKA rotary evaporators set new standards for safety, efficiency and ease of use. These rotovaps offer excellent distilling solutions to the demanding user. All IKA RV 10 rotovapors are equipped with a motorized lift with safety stop function. The comprehensive safety features also include interval operation, smooth start, end

Chapter 14: Solvent Removal

2. Prepare the rotovap. Using the handle, raise up the core part of the rotovap assely. If the solvent trap is more than half-full, detach it and empty it into the organic waste. Check that the rotovap’s bump trap and adapter are clean. If the sample will become a free-flowing powder after the solvent is removed (for instance, if you are

Operation of the Rotary Evaporator (Rotovap)

3. To close the system and thus activate the vacuum, turn the stopcock knob at the far end of the rotovap to align it with the vacuum (ie. turn until the arrow on the knob points straight down towards the attached tubing ie. knob is pointing to the “ON” position). The system is now under reduced pressure. 4.

How to Prevent Rotary Evaporator Glassware Implosion

Feb 16, 2019· As you know, rotovap systems use vacuum to reduce the boiling temperature of the solvent. However, the use of vacuum increases the risk of implosion of glassware. In this post, we take a look at the reasons why rotovap implosions occur, the dangers involved, and what you can do to prevent rotary evaporator glassware implosions and resulting